Street, road and site lighting

Category B streets and service roads: 0.3-0.8 cd/m² or 4-15 lx, bracket mounting on a pole, IP65 and operation at +45 °C.

What the facility needs

Street lighting is calculated on the carriageway surface. ShNK 2.01.05-24 (table 15) sets the average luminance of an improved surface and, as an alternative, the average horizontal illuminance: category B streets 0.6-1.0 cd/m² or 10-15 lx depending on traffic intensity, category V service roads 0.3-0.4 cd/m² or 4-6 lx; factory forecourts 10 lx (table 16). Uniformity: Lmin/Lmax at least 0.4 (clause 93), and for open areas Emax/Eavg at most 3:1 (clause 105): what matters is the minimum between the columns, not the maximum under one. Two numbers decide it: the column height and the spacing.

The second condition is the climate: Tashkent reached +44.3 °C on 19 July 2026, and during the dust storm of May 2025 PM10 reached 1,585 µg/m³ against a limit of 500. The housing goes well past +70 °C in the sun, and whether the flux survives to the third summer depends on how heat leaves it.

Why this series

Classic is mounted on a bracket, IP65, installed at 2 to 12 m. The extruded aluminium housing works as the heat sink.

Three colour temperatures: 3000 K for residential streets, 4000 K for site roads, 6500 K where the surface needs contrast.

Typical layout

An internal site road of ≈ 800 m, 7 m wide, 8 m columns, category V:

  • SKU 01 Classic 100W, spacing ≈ 30 m, single-sided arrangement, ≈ 27 pcs
  • installed load ≈ 2.7 kW

The Classic 100W flux is 13,000 lm per the header of the 2018 IES file; the file itself does not agree with its own curve (explained on the model page), so the figure is a calculated one. Flux-per-span method: E = F × UF × MF / (spacing × width) with UF 0.35 (the share of flux landing on the carriageway) and MF 0.63 (app. 1, table 3, streets; safety factor 1.6, MF = 1/1.6): 13,000 × 0.35 × 0.63 / (30 × 7) ≈ 14 lx, above the 6 lx for category V and the 10 lx for a category B street with up to 500 vehicles/h. The spacing changes with the road width and the surface class.

What the replacement gives

Before: the same road on 27 high-pressure sodium (HPS) 250 W lamps at 275 W with ballast, ≈ 7.4 kW. At the nominal flux of new lamps (30,000 lm, Lisma DNaT 250-5M) that is ≈ 30 lx, and ≈ 27 lx by 16,000 hours (LLMF 0.85): 3 to 5 times the category V target. The old layouts were calculated from the lamp that was available, not from the target.

After: ≈ 2.7 kW at ≈ 14 lx with no end-of-life drop: the target is met, not exceeded several times over. At 11 burning hours for 365 days a year the difference is ≈ 19,000 kWh a year; in UZS, by the tariff on the date of the calculation (see the savings calculator).

A calculated estimate under the stated assumptions, not guaranteed until measured on site. Figures marked ≈ are estimates.

Frequently asked questions

What is the illuminance norm for streets and grounds?

ShNK 2.01.05-24 (table 15) sets the average road surface luminance or, as an alternative, the average horizontal illuminance: category B streets 0.6-1.0 cd/m² or 10-15 lx depending on traffic, category V service roads 0.3-0.4 cd/m² or 4-6 lx, factory forecourts 10 lx (table 16). Uniformity: Lmin/Lmax of at least 0.4 (item 93).

What IP rating and operating temperature does a street luminaire have?

Classic is a bracket-mounted luminaire rated IP65 (also made in IP54), with a catalogue temperature range of -30 to +50 °C. The extruded aluminium body works as a heat sink: the flux kept by the third summer depends on heat removal. The temperature is a data sheet value from the catalogue; the test report is still in progress.

How many luminaires does a kilometre of road need?

The spacing comes from E = F × UF × MF / (spacing × width), with MF 0.63 for streets (app. 1, table 3). In the typical layout, an on-site road of about 800 m, 7 m wide, with 8 m poles, is covered by about 27 Classic 100W luminaires at about 30 m spacing: about 2.7 kW and about 14 lx against the 6 lx norm for category V. That is an estimate: spacing depends on road width and surface, and DIALux gives the final figure.

What replaces a 250 W HPS lamp on a street?

Older layouts were designed from the lamp that was there, not from the norm. In the typical layout, a road on 27 HPS luminaires (about 7.4 kW) gives about 30 lx, 3-5 times the norm for category V. The same 27 poles with Classic 100W give about 14 lx at about 2.7 kW: the norm is met rather than exceeded several times over. The figures are estimates and are not guaranteed before measurement on site.

Estimate the savings

Illuminance target
Space or zone Target, lx Plane and note
Category B streets, 500 to 2,000 vehicles/h 0.6 to 0.8 cd/m² or 10 to 15 lx average luminance of an improved surface; table 15
Category V service roads 0.3 to 0.4 cd/m² or 4 to 6 lx table 15; 4 lx on intermediate surfaces, 2 lx on low-grade ones, clause 84
Factory forecourts, non-traffic parts of category A and B squares 10 average horizontal on the surface; table 16, item 1
Pedestrian streets 4 to 6 6 in public centres, 4 elsewhere; table 16, item 2

Values per ShNK 2.01.05-24 “Natural and artificial lighting” (Ministry of Construction order No. 1/2-68 of 26 September 2024, Ministry of Justice registration No. 309 of 25 October 2024, text at lex.uz/ru/docs/7218587), checked against the text on 17 September 2026; the clause and table are given in every row. H is the horizontal plane at the stated height above the floor, V is vertical. The design target is set by your technical specifications, and we run the DIALux calculation against it.

Built for +45 °C

Tashkent hit +44.3 °C on 19 July 2026, and during the dust storm of May 2025 PM10 reached 1,585 µg/m³ against a limit of 500. The aluminium housing works as the heat sink: how much light is left by the third summer depends on it.

Blog

We will calculate your facility

Send a floor plan or your technical specifications: we return a DIALux calculation, a bill of materials and a payback period. Free of charge.

Request a calculation Downloads