SKU 01 Classic 50W
- Power 50 W
- Luminous flux up to 9,000 lm
- Ingress protection IP54 / IP65
515,200 UZS
incl. 12% VAT
Open the model
940,800 UZS
Price includes 12% VAT. Price list dated 21 September 2026.
Download IESA bracket-mounted street luminaire for roads, plant driveways, car parks and fuel station forecourts. Twice the flux of Classic 50W lets you widen the pole spacing. On short spans it is more than you need.
| Power | 100 W |
|---|---|
| Luminous flux | up to 18,000 lm 1 |
| Luminous efficacy | over 180 lm/W 1 |
| Ingress protection | IP54 / IP65 |
| Colour temperatures | 3000 / 4000 / 6500 K |
| Mounting height | 2 to 12 m |
| Dimensions | 1000×100×70 mm |
| Housing | Extruded aluminium profile |
| Ambient temperature | -30 to +50 °C 2 |
| Rated life | 50,000 h (L90), calculated 2 |
| LED lumen depreciation | no more than 5 % over the service life 2 |
| Warranty | 3 years |
| SKU | sku-01-classic-100 |
We are preparing the data sheet: Ra, percent flicker, UGR, supply voltage. Need one for your specification now? Ask our engineer.
C0-C180 C90-C270
The file is dated 2018 and comes from the HLT model of the same name. The calculated flux in the table above was obtained differently.
Beam angle 108° × 114° (C0 × C90 planes), from the 2018 IES file
2018 photometry taken from the HLT model of the same name. A new report is in progress. This file does not agree with itself: the site does not show numbers from it, and the explanation is under the curve on the model page.
14 models across four series: unit prices, per running metre for linear luminaires. Built from the model cards.
The warranty period is 3 years. It covers both failure of the luminaire and a drop in luminous flux; the terms are written into the contract. A faulty luminaire is replaced.
The page has an IES file, but it does not agree with itself: the integral of its intensity curve is not equal to the flux stated in it. The shape of the curve is right, but the numbers must not be used in a calculation. Ask the engineer for current photometry.
Calculated, from the power and the efficacy claimed for the LED modules. It is an upper bound, not a measurement of the assembled luminaire. The ANSI/IES LM-79 report is in progress; once we have it, the calculated values will be replaced with measured ones. Until then a design should use the flux from the IES file.
They depend on the batch size and the production load. We state them in the quotation.
Same optics and hardware, different power.
Model images are visualisations based on photographs of the actual products; the background and lighting are AI-generated, the geometry and construction match the product.